Gas Transmission and Supply Technologies
Objective
Osaka Gas uses discriminative gas detector for inflammable gas leak detection
in order to detect leak and to clear up the cause of leakage early.
Osaka Gas has one thousand several hundred of them, but there are the
following problems currently.
- Cannot measure of the gas concentration and
discriminate of a gas kind simultaneously
- To use six LR14 type dry cells, battery exchange cost is expended and industrial waste is produced.
In order to solve such problems, Osaka Gas developed the new "Discriminative
gas detector " which is superior in operability, power saving and quick
response.
Outline
Discriminative gas detector has two kinds of following catalytic combustion sensors.
- The sensor, which calling the M sensor detects
all inflammable gas
- The sensor, which calling the S sensor detects all inflammable gas except methane
Discriminative gas detector can measure sampling gas by these two sensors
simultaneously, and discriminate the kind of sampling gas by comparing
output.
Discrimination of gas is done by built-in microcomputer, and discrimination
result is displayed.

Specifications
| Principle | Catalytic combustion type, 4-sensor system |
|---|---|
| Discrimination gas | City gas (13A by a Japanese standard), methane, LPG, other combustibility gases |
| Detection range | 0-100 %LEL, 0-100 VOL% |
| Detection speed | 10 seconds Maximum (90% reply) |
| Power source | Four LR14-type dry cells |
| Weight | 2.0 kg |
| Size | 165(W)*86(D)*137(H)mm (Exclude the projection part) |
| Explosion prevention | EXibdIIAT3 |
Features
- Concentration measurement and discrimination
of a gas kind can be done simultaneously
- Automatic conversion of the concentration can
be done, if discriminated gas is LPG. (%LEL range only)
- User can exchange sensors by himself
- Small, light weight, and operation is easy
- Reply speed is quickly

Distributor
Osaka Gas Engineering Co., Ltd