Gas Transmission and Supply Technologies

Handy type gas detector (SP-206)
Pipeline & Facilities Engineering Dept. Pipeline Business Unit

Objective

Osaka Gas uses small-size inflammable gas detector for the purpose of leak test for under-grounding gas pipe and indoor gas pipe.
Osaka Gas developed new type small-size inflammable gas detector, which calling "Handy type gas detector", intend to operability improvement, initial cost reduction and running cost reduction.

Outline

The developed detector is ready for operation when the power switch is turned on. No initial adjustment at warming up is required. All of control circuits were designed so as to consume less power. Consequently, few batteries are required. The gas sensor is housed in a detachable cartridge, making it easy to replace and reducing running costs.

  • Introduction of an auto-zeroing system to eliminate dial adjustment
  • Use of an LED bar to indicate gas concentration
  • Drip-proof construction to allow for detection work with minimum care on rainy days
  • Introduction of a simplified gas flow rate check system to detect failure of the suction pump, clogging of the filter, and other abnormal conditions
  • Improved maintainability (replacement of battery and parts)

Specification

Principle Hot-wire-type semiconductor
Target gas City gas (13A by a Japanese standard), LPG, and other inflammable gases
Detectable range 10-10,000 ppm
Detection speed Within 3 seconds
Power source Three LR6-type dry cells
Battery lifE 9 hours for continuous operation (alkaline battery)
Size 35(W)~57(D)~128(H) mm (Exclude the projection part)
Weight 320g

Features

  • Small size and light weight
  • Can adjust with power on automatically
  • Display the gas density and setting sensitivity with a LED lamp
  • Warning is done by all density indication lamps turn on, if abnormality adjustment, flow quantity fall, and voltage fall of battery cell
  • Exchange of a battery and exchange of a sensor are easy